产品简介
Honeywell霍尼韦尔气体探测器XNX侦测器XNX-AMAI-MNNNN
Honeywell霍尼韦尔气体探测器XNX侦测器XNX-AMAI-MNNNN
产品价格:¥1
上架日期:2018-06-24 17:42:21
产地:美国
发货地:上海
供应数量:不限
最少起订:1个
浏览量:3818
资料下载:暂无资料下载
其他下载:暂无相关下载
详细说明

    Honeywell霍尼韦尔气体探测器XNX通用侦测发报器 上海宛畅XNX-AMAI-MNNNN

    XNX is an extremely flexible gas transmitter that can be configured to accept an bbbbb from any of the Honeywell Analytics range of gas sensor technologies.

    It can also be configured to provide all the industry standard output signals; a key feature of the XNX transmitter is that it comes with HART over 4-20mA as standard. This enables users to have a single type of interface to all their gas detection needs, even when different types of detectors are employed.


    XNX is ATEX, IECEx, UL, CSA and SIL2 approved and is housed in a flameproof enclosure  available in either marine grade painted aluminium LM25 or stainless steel 316. A large backlit multilingual LCD bbbbbly indicates the unit’s  status using a combination of text, digits and icons. Users can configure or conduct routine maintenance via magnet switches without ever needing to open the unit. An optional local IS HART® terminal port is also available if  local interrogation is required. Local LEDs are also provided to indicate the unit’s status at a glance.


    1. XNX Universal Transmitter- Flammable Standard Temperature with MPD sensor

    XNX Universal transmitter for the Multi - Purpose Detector (MPD) sensor for flammable gases.

    1.1. INSTRUMENT

    XNX Aluminium Transmitter ATEX/IEC/INMETRO with MPD Flammable Catalytic Sensor 0-100%LEL


    XNX-AMAV-NNCB1

    XNX Gas Detector, HART® over 4-20mA output, ATEX/IECEx/INMETRO, 4 x M25 entries, painted Aluminium, includes MPD catalytic sensor 0-100%LEL

    XNX-AMAV-NHCB1

    XNX Gas Detector, HART® over 4-20mA output and local HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted Aluminium, includes MPD catalytic sensor 0-100%LEL

    XNX-AMAV-RNCB1

    XNX Gas Detector, HART® over 4-20mA output and 3 fault/alarm relays, ATEX/IECEx/INMETRO, 4 x M25 entries, painted Aluminium, includes MPD catalytic sensor 0-100%LEL

    XNX-AMAV-RHCB1

    XNX Gas Detector, HART® over 4-20mA output, 3 fault/alarm relays and local HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted Aluminium, includes MPD catalytic sensor 0-100%LEL

    XNX-AMAV-MNCB1

    XNX Gas Detector, HART® over 4-20mA and Modbus output, ATEX/IECEx/INMETRO, 4 x M25 entries, painted Aluminium, includes MPD catalytic sensor 0-100%LEL

    XNX-AMAV-MHCB1

    XNX Gas Detector, HART® over 4-20mA and Modbus output and local HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted Aluminium, includes MPD catalytic sensor 0-100%LEL

    XNX-AMAV-NNCB2

    XNX Gas Detector, HART® over 4-20mA output, ATEX/IECEx/INMETRO, 4 x M25 entries, painted Aluminium, includes MPD catalytic sensor 0-101%LEL

    XNX-AMAV-NHCB2

    XNX Gas Detector, HART® over 4-20mA output and local HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted Aluminium, includes MPD catalytic sensor 0-101%LEL



    XNX Stainless Steel Transmitter ATEX/IEC with MPD Flammable Catalytic Sensor 0-100%LEL

    XNX-AMSV-NNCB1

    XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, including MPD catalytic sensor 0-100%LEL.

    XNX-AMSV-NHCB1

    XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with local HART® interface port, including MPD catalytic sensor 0-100%LEL.

    XNX-AMSV-RNCB1

    XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with alarm and fault relay outputs, including MPD catalytic sensor 0-100%LEL.

    XNX-AMSV-RHCB1

    XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with alarm and fault relay outputs and local HART® interface port, including MPD catalytic sensor 0-100%LEL.

    XNX-AMSV-MNCB1

    XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with Modbus® output, including MPD catalytic sensor 0-100%LEL.

    XNX-AMSV-MHCB1

    XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with Modbus® output and local HART® interface port, including MPD catalytic sensor 0-100%LEL.

    XNX-AMSV-FNCB1

    XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with optional Foundation Fieldbus™ output, including MPD catalytic sensor 0-100%LEL.

    XNX-AMSV-FHCB1

    XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with optional Foundation Fieldbus™ output and local HART® interface port, including MPD catalytic sensor 0-100%LEL.

    XNX Aluminium Transmitter ATEX/IEC/INMETRO with MPD IR Hydrocarbon (Propane) Sensor 0-100%LEL

    XNX-AMAV-NNIF1

    XNX Gas Detector, HART® over 4-20mA output, ATEX/IECEx/INMETRO, 4 x M25 entries, painted Aluminium, includes MPD IR hydrocarbon (Propane) sensor 0-100%LEL

    XNX-AMAV-NHIF1

    XNX Gas Detector, HART® over 4-20mA output and local HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted Aluminium, includes MPD IR hydrocarbon (Propane) sensor 0-100%LEL

    XNX-AMAV-RNIF1

    XNX Gas Detector, HART® over 4-20mA output and 3 fault/alarm relays, ATEX/IECEx/INMETRO, 4 x M25 entries, painted Aluminium, includes MPD IR hydrocarbon (Propane) sensor 0-100%LEL

    XNX-AMAV-RHIF1

    XNX Gas Detector, HART® over 4-20mA output, 3 fault/alarm relays and local HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted Aluminium, includes MPD IR hydrocarbon (Propane) sensor 0-100%LEL

    XNX-AMAV-MNIF1

    XNX Gas Detector, HART® over 4-20mA and Modbus output, ATEX/IECEx/INMETRO, 4 x M25 entries, painted Aluminium, includes MPD IR hydrocarbon (Propane) sensor 0-100%LEL

    XNX-AMAV-MHIF1

    XNX Gas Detector, HART® over 4-20mA and Modbus output and local HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted Aluminium, includes MPD IR hydrocarbon (Propane) sensor 0-100%LEL

    XNX-AMAV-FNIF1

    XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output, ATEX/IECEx/INMETRO, 4 x M25 entries, painted Aluminium, includes MPD IR hydrocarbon (Propane) sensor 0-100%LEL

    XNX-AMAV-FHIF1

    XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output and local HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted Aluminium, includes MPD IR hydrocarbon (Propane) sensor 0-100%LEL

    XNX Stainless Steel Transmitter ATEX/IEC with MPD IR Hydrocarbon (Propane) Sensor 0-100%LEL

    XNX-AMSV-NNIF1

    XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, including MPD IR flammable (propane) sensor 0-100%LEL.

    XNX-AMSV-NHIF1

    XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with local HART® interface port, including MPD IR flammable sensor 0-100%LEL.

    XNX-AMSV-RNIF1

    XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with alarm and fault relay outputs, including MPD IR flammable sensor 0-100%LEL.

    XNX-AMSV-RHIF1

    XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with alarm and fault relay outputs and local HART® interface port, including MPD IR flammable sensor 0-100%LEL.

    XNX-AMSV-MNIF1

    XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with Modbus® output, including MPD IR flammable sensor 0-100%LEL.

    XNX-AMSV-MHIF1

    XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with Modbus® output and local HART® interface port, including MPD IR flammable sensor 0-100%LEL.

    XNX-AMSV-FNIF1

    XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with optional Foundation Fieldbus™ output, including MPD IR flammable sensor 0-100%LEL.

    XNX-AMSV-FHIF1

    XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with optional Foundation Fieldbus™ output and local HART® interface port, including MPD IR flammable sensor 0-100%LEL.

    XNX Aluminium Transmitter ATEX/IEC/INMETRO with MPD Infrared Methane Sensor 0-100%LEL (0-5%V/V).

    XNX-AMAV-NNIV1

    XNX Gas Detector, HART® over 4-20mA output, ATEX/IECEx/INMETRO, 4 x M25 entries, painted Aluminium, includes MPD IR hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v)

    XNX-AMAV-NHIV1

    XNX Gas Detector, HART® over 4-20mA output and local HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted Aluminium, includes MPD IR hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v)

    XNX-AMAV-RNIV1

    XNX Gas Detector, HART® over 4-20mA output and 3 fault/alarm relays, ATEX/IECEx/INMETRO, 4 x M25 entries, painted Aluminium, includes MPD IR hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v)

    XNX-AMAV-RHIV1

    XNX Gas Detector, HART® over 4-20mA output, 3 fault/alarm relays and local HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted Aluminium, includes MPD IR hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v)

    XNX-AMAV-MNIV1

    XNX Gas Detector, HART® over 4-20mA and Modbus output, ATEX/IECEx/INMETRO, 4 x M25 entries, painted Aluminium, includes MPD IR hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v)

    XNX-AMAV-MHIV1

    XNX Gas Detector, HART® over 4-20mA and Modbus output and local HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted Aluminium, includes MPD IR hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v)

    XNX-AMAV-FNIV1

    XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output, ATEX/IECEx/INMETRO, 4 x M25 entries, painted Aluminium, includes MPD IR hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v)

    XNX-AMAV-FHIV1

    XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output and local HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted Aluminium, includes MPD IR hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v)

    XNX Stainless Steel Transmitter ATEX/IEC with MPD Infrared Methane Sensor 0-100%LEL (0-5%V/V).

    XNX-AMSV-NNIV1

    XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, including MPD IR methane sensor 0-100%LEL (0-5%V/V).

    XNX-AMSV-NHIV1

    XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with optional local HART® interface port, including MPD IR methane sensor 0-100%LEL (0-5%V/V).

    XNX-AMSV-RNIV1

    XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with optional alarm and fault relay outputs, including MPD IR methane sensor 0-100%LEL (0-5%V/V).

    XNX-AMSV-RHIV1

    XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with optional alarm and fault relay outputs and local HART® interface port, including MPD IR methane sensor 0-100%LEL (0-5%V/V).

    XNX-AMSV-MNIV1

    XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with optional Modbus® output, including MPD IR methane sensor 0-100%LEL (0-5%V/V).

    XNX-AMSV-MHIV1

    XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with optional Modbus® output and local HART® interface port, including MPD IR methane sensor 0-100%LEL (0-5%V/V).

    XNX-AMSV-FNIV1

    XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with optional Foundation Fieldbus™ output, including MPD IR methane sensor 0-5%V/V.

    XNX-AMSV-FHIV1

    XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with optional Foundation Fieldbus™ output and local HART® interface port, including MPD IR methane sensor 0-5%V/V.

    XNX Aluminium Transmitter ATEX/IEC/INMETRO with MPD Infrared CO2 Sensor 0-5%V/V.

    XNX-AMAV-NNIC1

    XNX Gas Detector, HART® over 4-20mA output, ATEX/IECEx/INMETRO, 4 x M25 entries, painted Aluminium, includes MPD IR CO2 sensor 0-5%v/v

    XNX-AMAV-NHIC1

    XNX Gas Detector, HART® over 4-20mA output and local HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted Aluminium, includes MPD IR CO2 sensor 0-5%v/v

    XNX-AMAV-RNIC1

    XNX Gas Detector, HART® over 4-20mA output and 3 fault/alarm relays, ATEX/IECEx/INMETRO, 4 x M25 entries, painted Aluminium, includes MPD IR CO2 sensor 0-5%v/v

    XNX-AMAV-RHIC1

    XNX Gas Detector, HART® over 4-20mA output, 3 fault/alarm relays and local HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted Aluminium, includes MPD IR CO2 sensor 0-5%v/v

    XNX-AMAV-MNIC1

    XNX Gas Detector, HART® over 4-20mA and Modbus output, ATEX/IECEx/INMETRO, 4 x M25 entries, painted Aluminium, includes MPD IR CO2 sensor 0-5%v/v

    XNX-AMAV-MHIC1

    XNX Gas Detector, HART® over 4-20mA and Modbus output and local HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted Aluminium, includes MPD IR CO2 sensor 0-5%v/v

    XNX-AMAV-FNIC1

    XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output, ATEX/IECEx/INMETRO, 4 x M25 entries, painted Aluminium, includes MPD IR CO2 sensor 0-5%v/v

    XNX-AMAV-FHIC1

    XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output and local HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted Aluminium, includes MPD IR CO2 sensor 0-5%v/v

    XNX Stainless Steel Transmitter ATEX/IEC with MPD Infrared CO2 Sensor 0-5%V/V.

    XNX-AMSV-NNIC1

    XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, including MPD IR CO2 sensor 0-5%V/V.

    XNX-AMSV-NHIC1

    XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with local HART® interface port, including MPD IR CO2 sensor 0-5%V/V.

    XNX-AMSV-RNIC1

    XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with alarm and fault relay outputs, including MPD IR CO2 sensor 0-5%V/V.

    XNX-AMSV-RHIC1

    XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with alarm and fault relay outputs and local HART® interface port, including MPD IR CO2 sensor 0-5%V/V.

    XNX-AMSV-MNIC1

    XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with Modbus® output, including MPD IR CO2 sensor 0-5%V/V.

    XNX-AMSV-MHIC1

    XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with Modbus® output and local HART® interface port, including MPD IR CO2 sensor 0-5%V/V.

    XNX-AMSV-FNIC1

    XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with optional Foundation Fieldbus™ output, including MPD IR CO2 sensor 0-5%V/V.

    XNX-AMSV-FHIC1

    XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with optional Foundation Fieldbus™ output and local HART® interface port, including MPD IR CO2 sensor 0-5%V/V.

    XNX Aluminium Transmitter UL/CSA with MPD Catalytic Sensor 0-100%LEL

    XNX-UTAV-NNCB1

    XNX Gas Detector, HART® over 4-20mA output, UL/CSA, 4 x 3/4"NPT entries, painted Aluminium, includes MPD catalytic sensor 0-100%LEL

    XNX-UTAV-NHCB1

    XNX Gas Detector, HART® over 4-20mA output and local HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted Aluminium, includes MPD catalytic sensor 0-100%LEL

    XNX-UTAV-RNCB1

    XNX Gas Detector, HART® over 4-20mA output and 3 fault/alarm relays, UL/CSA, 4 x 3/4"NPT entries, painted Aluminium, includes MPD catalytic sensor 0-100%LEL

    XNX-UTAV-RHCB1

    XNX Gas Detector, HART® over 4-20mA output, 3 fault/alarm relays and local HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted Aluminium, includes MPD catalytic sensor 0-100%LEL

    XNX-UTAV-MNCB1

    XNX Gas Detector, HART® over 4-20mA and Modbus output, UL/CSA, 4 x 3/4"NPT entries, painted Aluminium, includes MPD catalytic sensor 0-100%LEL

    XNX-UTAV-MHCB1

    XNX Gas Detector, HART® over 4-20mA and Modbus output and local HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted Aluminium, includes MPD catalytic sensor 0-100%LEL

    XNX-UTAV-FNCB1

    XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output, UL/CSA, 4 x 3/4"NPT entries, painted Aluminium, includes MPD catalytic sensor 0-100%LEL

    XNX-UTAV-FHCB1

    XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output and local HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted Aluminium, includes MPD catalytic sensor 0-100%LEL

    XNX Stainless Steel Transmitter UL/CSA with MPD Catalytic Sensor 0-100%LEL

    XNX-UTSV-NNCB1

    XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, including MPD catalytic sensor 0-100%LEL.

    XNX-UTSV-NHCB1

    XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with local HART® interface port, including MPD catalytic sensor 0-100%LEL.

    XNX-UTSV-RNCB1

    XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with alarm and fault relay outputs, including MPD catalytic sensor 0-100%LEL.

    XNX-UTSV-RHCB1

    XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with alarm and fault relay outputs and local HART® interface port, including MPD catalytic sensor 0-100%LEL.

    XNX-UTSV-MNCB1

    XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with Modbus® output, including MPD catalytic sensor 0-100%LEL.

    XNX-UTSV-MHCB1

    XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with Modbus® output and local HART® interface port, including MPD catalytic sensor 0-100%LEL.

    XNX-UTSV-FNCB1

    XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with optional Foundation Fieldbus™ output, including MPD catalytic sensor 0-100%LEL.

    XNX-UTSV-FHCB1

    XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with optional Foundation Fieldbus™ output and local HART® interface port, including MPD catalytic sensor 0-100%LEL.

    XNX Aluminium Transmitter UL/CSA with MPD Infrared Hydrocarbon (Propane) Sensor 0-100%LEL

    XNX-UTAV-NNIF1

    XNX Gas Detector, HART® over 4-20mA output, UL/CSA, 4 x 3/4"NPT entries, painted Aluminium, includes MPD IR hydrocarbon (Propane) sensor 0-100%LEL

    XNX-UTAV-NHIF1

    XNX Gas Detector, HART® over 4-20mA output and local HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted Aluminium, includes MPD IR hydrocarbon (Propane) sensor 0-100%LEL

    XNX-UTAV-RNIF1

    XNX Gas Detector, HART® over 4-20mA output and 3 fault/alarm relays, UL/CSA, 4 x 3/4"NPT entries, painted Aluminium, includes MPD IR hydrocarbon (Propane) sensor 0-100%LEL

    XNX-UTAV-RHIF1

    XNX Gas Detector, HART® over 4-20mA output, 3 fault/alarm relays and local HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted Aluminium, includes MPD IR hydrocarbon (Propane) sensor 0-100%LEL

    XNX-UTAV-MNIF1

    XNX Gas Detector, HART® over 4-20mA and Modbus output, UL/CSA, 4 x 3/4"NPT entries, painted Aluminium, includes MPD IR hydrocarbon (Propane) sensor 0-100%LEL

    XNX-UTAV-MHIF1

    XNX Gas Detector, HART® over 4-20mA and Modbus output and local HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted Aluminium, includes MPD IR hydrocarbon (Propane) sensor 0-100%LEL

    XNX-UTAV-FNIF1

    XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output, UL/CSA, 4 x 3/4"NPT entries, painted Aluminium, includes MPD IR hydrocarbon (Propane) sensor 0-100%LEL

    XNX-UTAV-FHIF1

    XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output and local HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted Aluminium, includes MPD IR hydrocarbon (Propane) sensor 0-100%LEL


    XNX Stainless Steel Transmitter UL/CSA with MPD Infrared Hydrocarbon (Propane) Sensor 0-100%LEL


    XNX-UTSV-NNIF1

    XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, including MPD IR flammable sensor 0-100%LEL.

    XNX-UTSV-NHIF1

    XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with local HART® interface port, including MPD IR flammable sensor 0-100%LEL.

    XNX-UTSV-RNIF1

    XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with alarm and fault relay outputs, including MPD IR flammable sensor 0-100%LEL.

    XNX-UTSV-RHIF1

    XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with alarm and fault relay outputs and local HART® interface port, including MPD IR flammable sensor 0-100%LEL.

    XNX-UTSV-MNIF1

    XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with Modbus® output, including MPD IR flammable sensor 0-100%LEL.

    XNX-UTSV-MHIF1

    XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with Modbus® output and local HART® interface port, including MPD IR flammable sensor 0-100%LEL.

    XNX-UTSV-FNIF1

    XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with optional Foundation Fieldbus™ output, including MPD IR flammable sensor 0-100%LEL.

    XNX -UTSV-FHIF1

    XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with optional Foundation Fieldbus™ output and local HART® interface port, including MPD IR flammable sensor 0-100%LEL.

    XNX Aluminium Transmitter UL/CSA with MPD Infrared Methane Sensor 0-100%LEL (0-5%V/V).

    XNX-UTAV-NNIV1

    XNX Gas Detector, HART® over 4-20mA output, UL/CSA, 4 x 3/4"NPT entries, painted Aluminium, includes MPD IR hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v)

    XNX-UTAV-NHIV1

    XNX Gas Detector, HART® over 4-20mA output and local HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted Aluminium, includes MPD IR hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v)

    XNX-UTAV-RNIV1

    XNX Gas Detector, HART® over 4-20mA output and 3 fault/alarm relays, UL/CSA, 4 x 3/4"NPT entries, painted Aluminium, includes MPD IR hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v)

    XNX-UTAV-RHIV1

    XNX Gas Detector, HART® over 4-20mA output, 3 fault/alarm relays and local HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted Aluminium, includes MPD IR hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v)

    XNX-UTAV-MNIV1

    XNX Gas Detector, HART® over 4-20mA and Modbus output, UL/CSA, 4 x 3/4"NPT entries, painted Aluminium, includes MPD IR hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v)

    XNX-UTAV-MHIV1

    XNX Gas Detector, HART® over 4-20mA and Modbus output and local HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted Aluminium, includes MPD IR hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v)

    XNX-UTAV-FNIV1

    XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output, UL/CSA, 4 x 3/4"NPT entries, painted Aluminium, includes MPD IR hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v)

    XNX-UTAV-FHIV1

    XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output and local HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted Aluminium, includes MPD IR hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v)

    XNX Stainless Steel Transmitter UL/CSA with MPD Infrared Methane Sensor 0-100%LEL (0-5%V/V).

    XNX-UTSV-NNIV1

    XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, including MPD IR methane sensor 0-100%LEL (0-5%V/V).

    XNX-UTSV-NHIV1

    XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with optional local HART® interface port, including MPD IR methane sensor 0-100%LEL (0-5%V/V).

    XNX-UTSV-RNIV1

    XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with optional alarm and fault relay outputs, including MPD IR methane sensor 0-100%LEL (0-5%V/V).

    XNX-UTSV-RHIV1

    XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with optional alarm and fault relay outputs and local HART® interface port, including MPD IR methane sensor 0-100%LEL (0-5%V/V).

    XNX-UTSV-MNIV1

    XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with optional Modbus® output, including MPD IR methane sensor 0-100%LEL (0-5%V/V).

    XNX-UTSV-MHIV1

    XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with optional Modbus® output and local HART® interface port, including MPD IR methane sensor 0-100%LEL (0-5%V/V).

    XNX-UTSV-FNIV1

    XNX transmitter, HART® over 4-20mA output,UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with optional Foundation Fieldbus™ output, including MPD IR methane sensor 0-5%V/V.

    XNX-UTSV-FHIV1

    XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with optional Foundation Fieldbus™ output and local HART® interface port, including MPD IR methane sensor 0-5%V/V.

    XNX Aluminium Transmitter UL/CSA with MPD Infrared CO2 Sensor 0-5%V/V.

    XNX-UTAV-NNIC1

    XNX Gas Detector, HART® over 4-20mA output, UL/CSA, 4 x 3/4"NPT entries, painted Aluminium, includes MPD IR CO2 sensor 0-5%v/v

    XNX-UTAV-NHIC1

    XNX Gas Detector, HART® over 4-20mA output and local HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted Aluminium, includes MPD IR CO2 sensor 0-5%v/v

    XNX-UTAV-RNIC1

    XNX Gas Detector, HART® over 4-20mA output and 3 fault/alarm relays, UL/CSA, 4 x 3/4"NPT entries, painted Aluminium, includes MPD IR CO2 sensor 0-5%v/v

    XNX-UTAV-RHIC1

    XNX Gas Detector, HART® over 4-20mA output, 3 fault/alarm relays and local HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted Aluminium, includes MPD IR CO2 sensor 0-5%v/v

    XNX-UTAV-MNIC1

    XNX Gas Detector, HART® over 4-20mA and Modbus output, UL/CSA, 4 x 3/4"NPT entries, painted Aluminium, includes MPD IR CO2 sensor 0-5%v/v

    XNX-UTAV-MHIC1

    XNX Gas Detector, HART® over 4-20mA and Modbus output and local HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted Aluminium, includes MPD IR CO2 sensor 0-5%v/v

    XNX-UTAV-FNIC1

    XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output, UL/CSA, 4 x 3/4"NPT entries, painted Aluminium, includes MPD IR CO2 sensor 0-5%v/v

    XNX-UTAV-FHIC1

    XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output and local HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted Aluminium, includes MPD IR CO2 sensor 0-5%v/v


    XNX Stainless Steel Transmitter UL/CSA with MPD Infrared CO2 Sensor 0-5%V/V.


    XNX-UTSV-NNIC1

    XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, including MPD IR CO2 sensor 0-5%V/V.

    XNX-UTSV-NHIC1

    XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with local HART® interface port, including MPD IR CO2 sensor 0-5%V/V.

    XNX-UTSV-RNIC1

    XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with alarm and fault relay outputs, including MPD IR CO2 sensor 0-5%V/V.

    XNX-UTSV-RHIC1

    XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with alarm and fault relay outputs and local HART® interface port, including MPD IR CO2 sensor 0-5%V/V.

    XNX-UTSV-MNIC1

    XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with Modbus® output, including MPD IR CO2 sensor 0-5%V/V.

    XNX-UTSV-MHIC1

    XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with Modbus® output and local HART® interface port, including MPD IR CO2 sensor 0-5%V/V.

    XNX-UTSV-FNIC1

    XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with optional Foundation Fieldbus™ output, including MPD IR CO2 sensor 0-5%V/V.

    XNX-UTSV-FHIC1

    XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with optional Foundation Fieldbus™ output and local HART® interface port, including MPD IR CO2 sensor 0-5%V/V.


    1.2. SPARE MPD SENSORS


    MPD: Multi-Purpose Detector (mV) - ATEX

    MPD-AMCB1

    XNX MPD ATEX/IEC SENSOR CAT 0-100%LEL

    MPD-AMIV1

    XNX MPD ATEX/IEC SENSOR IR CH4 0-100%LEL

    MPD-AMIF1

    XNX MPD ATEX/IEC SENSOR IR 0-100%LEL

    MPD-AMIC1

    XNX MPD ATEX/IEC SENSOR IR CO2 0-5%VV

    MPD: Multi-Purpose Detector (mV) - UL/CSA

    MPD-UTCB1

    XNX MPD UL/CSA SENSOR CAT 0-100%LEL

    MPD-UTIV1

    XNX MPD UL/CSA SENSOR IR CH4 0-100%LEL

    MPD-UTIF1

    XNX MPD UL/CSA SENSOR IR 0-100%LEL

    MPD-UTIC1

    XNX MPD UL/CSA SENSOR IR CO2 0-5%VV

    1.3. SPARE MPD REPLACEABLE CARTRIDGES


    1226A0359

    XNX MPD CAT CARTRIDGE 0-100%LEL

    1226-0300

    XNX MPD IR CARTRIDGE 0-100%LEL

    1226-0301

    XNX MPD IR CARTRIDGE CO2 0-5%VV

    1226-0299

    XNX MPD IR CARTRIDGE CH4 0-100%LEL


    2. XNX Universal Transmitter- for use with Sensepoint HT or 705 HT Flammable Sensor


    XNX Universal Transmitter excluding Sensepoint High Temp or 705 HT Sensor or remote configurations of MPD. Order required sensor separabbby from other appropriate section of price list.


    2.1. INSTRUMENT


    XNX Aluminium Transmitter ATEX/IEC for use with Sensepoint High Temperature Sensor


    XNX-AMAV-NNNNN

    XNX Transmitter, HART® over 4-20mA output, ATEX/IECEx, 5 x M25 entries, painted Aluminium, configured for Sensepoint High Temperature Sensor

    XNX-AMAV-NHNNN

    XNX Transmitter, HART® over 4-20mA output and local HART® interface port, ATEX/IECEx, 4 x M25 entries, painted Aluminium, configured for Sensepoint High Temperature Sensor

    XNX-AMAV-RNNNN

    XNX Transmitter, HART® over 4-20mA output and 3 fault/alarm relays, ATEX/IECEx, 5 x M25 entries, painted Aluminium, configured for Sensepoint High Temperature Sensor

    XNX-AMAV-RHNNN

    XNX Transmitter, HART® over 4-20mA output and 3 fault/alarm relays and local HART® interface port, ATEX/IECEx, 4 x M25 entries, painted Aluminium, configured for Sensepoint High Temperature Sensor

    XNX-AMAV-MNNNN

    XNX Transmitter, HART® over 4-20mA and Modbus output, ATEX/IECEx, 5 x M25 entries, painted Aluminium, configured for Sensepoint High Temperature Sensor

    XNX-AMAV-MHNNN

    XNX Transmitter, HART® over 4-20mA and Modbus output and local HART® interface port, ATEX/IECEx, 4 x M25 entries, painted Aluminium, configured for Sensepoint High Temperature Sensor

    XNX-AMAV-FNNNN

    XNX Transmitter, HART® over 4-20mA and Foundation Fieldbus™ output, ATEX/IECEx, 5 x M25 entries, painted Aluminium, configured for Sensepoint High Temperature Sensor

    XNX-AMAV-FHNNN

    XNX Transmitter, HART® over 4-20mA and Foundation Fieldbus™ output and local HART® interface port, ATEX/IECEx, 4 x M25 entries, painted Aluminium, configured for Sensepoint High Temperature Sensor

    XNX Stainless Steel Transmitter ATEX/IEC for use with Sensepoint High Temperature Sensor

    XNX-AMSV-NNNNN

    XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, configured for mV sensors.

    XNX-AMSV-NHNNN

    XNX transmitter, HART® over 4-20mA output,  ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with local HART® interface port, configured for mV sensors.

    XNX-AMSV-RNNNN

    XNX transmitter, HART® over 4-20mA output,  ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with alarm and fault relay outputs, configured for mV sensors.

    XNX-AMSV-RHNNN

    XNX transmitter, HART® over 4-20mA output,  ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with alarm and fault relay outputs and local HART® interface port, configured for mV sensors.

    XNX-AMSV-MNNNN

    XNX transmitter, HART® over 4-20mA output,  ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with Modbus® output, configured for mV sensors.

    XNX-AMSV-MHNNN

    XNX transmitter, HART® over 4-20mA output,  ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with Modbus® output and local HART® interface port, configured for mV sensors.

    XNX-AMSV-FNNNN

    XNX transmitter, HART® over 4-20mA output,  ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with optional Foundation Fieldbus™ output, configured for mV sensors.

    XNX-AMSV-FHNNN

    XNX transmitter, HART® over 4-20mA output,  ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with optional Foundation Fieldbus™ output and local HART® interface port, configured for mV sensors.


    XNX Aluminium Transmitter UL/CSA for use with 705 High Temperature Sensor


    XNX-UTAV-NNNNN

    XNX Transmitter, HART® over 4-20mA output, UL/CSA, 5 x 3/4"NPT entries, painted Aluminium, configured for 705 High Temperature Sensor

    XNX-UTAV-NHNNN

    XNX Transmitter, HART® over 4-20mA output and local HART® interface port, UL/CSA, 4 x 3/4"NPT entries, painted Aluminium, configured for 705 High Temperature Sensor

    XNX-UTAV-RNNNN

    XNX Transmitter, HART® over 4-20mA output and 3 fault/alarm relays, UL/CSA, 5 x 3/4"NPT entries, painted Aluminium, configured for 705 High Temperature Sensor

    XNX-UTAV-RHNNN

    XNX Transmitter, HART® over 4-20mA output and 3 fault/alarm relays and local HART® interface port, UL/CSA, 4 x 3/4"NPT entries, painted Aluminium, configured for 705 High Temperature Sensor

    XNX-UTAV-MNNNN

    XNX Transmitter, HART® over 4-20mA and Modbus output, UL/CSA, 5 x 3/4"NPT entries, painted Aluminium, configured for 705 High Temperature Sensor

    XNX-UTAV-MHNNN

    XNX Transmitter, HART® over 4-20mA and Modbus output and local HART® interface port, UL/CSA, 4 x 3/4"NPT entries, painted Aluminium, configured for 705 High Temperature Sensor

    XNX-UTAV-FNNNN

    XNX Transmitter, HART® over 4-20mA and Foundation Fieldbus™ output, UL/CSA, 5 x 3/4"NPT entries, painted Aluminium, configured for 705 High Temperature Sensor

    XNX-UTAV-FHNNN

    XNX Transmitter, HART® over 4-20mA and Foundation Fieldbus™ output and local HART® interface port, UL/CSA, 4 x 3/4"NPT entries, painted LM25, configured for 705 High Temperature Sensor


    XNX Stainless Steel Transmitter UL/CSA for use with model 705 High Temperature Sensor


    XNX-UTSV-NNNNN

    XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, configured for mV sensors.

    XNX-UTSV-NHNNN

    XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with local HART® interface port, configured for mV sensors.

    XNX-UTSV-RNNNN

    XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with alarm and fault relay outputs, configured for mV sensors.

    XNX-UTSV-RHNNN

    XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with alarm and fault relay outputs and local HART® interface port, configured for mV sensors.

    XNX-UTSV-MNNNN

    XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with Modbus® output, configured for mV sensors.

    XNX-UTSV-MHNNN

    XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with Modbus® output and local HART® interface port, configured for mV sensors.

    XNX-UTSV-FNNNN

    XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with optional Foundation Fieldbus™ output, configured for mV sensors.

    XNX-UTSV-FHNNN

    XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with optional Foundation Fieldbus™ output and local HART® interface port, configured for mV sensors.



    3. XNX Universal Transmitter- for use with XNX Toxic & Oxygen Sensors


    XNX Universal Transmitter excluding toxic or oxygen sensor. Order required sensor separabbby from the XNX toxic and oygen sensors section below.


    3.1. INSTRUMENT


    XNX Aluminium Transmitter ATEX/IEC/INMETRO  for use with XNX Toxic and Oxygen Sensors


    XNX-AMAE-NNNNN

    XNX Transmitter, HART® over 4-20mA output, ATEX/IECEx/INMETRO, 4 x M25 entries, painted Aluminium, configured for XNX toxic and oxygen sensors

    XNX-AMAE-NHNNN

    XNX Transmitter, HART® over 4-20mA output and local HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted Aluminium, configured for XNX toxic and oxygen sensors

    XNX-AMAE-RNNNN

    XNX Transmitter, HART® over 4-20mA output and 3 fault/alarm relays, ATEX/IECEx/INMETRO, 4 x M25 entries, painted Aluminium, configured for XNX toxic and oxygen sensors

    XNX-AMAE-RHNNN

    XNX Transmitter, HART® over 4-20mA output and 3 fault/alarm relays and local HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted Aluminium, configured for XNX toxic and oxygen sensors

    XNX-AMAE-MNNNN

    XNX Transmitter, HART® over 4-20mA and Modbus output, ATEX/IECEx/INMETRO, 4 x M25 entries, painted Aluminium, configured for XNX toxic and oxygen sensors

    XNX-AMAE-MHNNN

    XNX Transmitter, HART® over 4-20mA and Modbus output and local HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted Aluminium, configured for XNX toxic and oxygen sensors

    XNX-AMAE-FNNNN

    XNX Transmitter, HART® over 4-20mA and Foundation Fieldbus™ output, ATEX/IECEx/INMETRO, 4 x M25 entries, painted Aluminium, configured for XNX toxic and oxygen sensors

    XNX-AMAE-FHNNN

    XNX Transmitter, HART® over 4-20mA and Foundation Fieldbus™ output and local HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted Aluminium, configured for XNX toxic and oxygen sensors


    XNX Stainless Steel Transmitter ATEX/IEC for use with XNX Toxic and Oxygen Sensors

    XNX-AMSE-NNNNN

    XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, configured for XNX toxic and oxygen sensors.

    XNX-AMSE-NHNNN

    XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with local HART® interface port, configured for XNX toxic and oxygen sensors.

    XNX-AMSE-RNNNN

    XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with alarm and fault relay outputs, configured for XNX toxic and oxygen sensors.

    XNX-AMSE-RHNNN

    XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with alarm and fault relay outputs and local HART® interface port, configured for XNX toxic and oxygen sensors.

    XNX-AMSE-MNNNN

    XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with Modbus® output, configured for XNX toxic and oxygen sensors.

    XNX-AMSE-MHNNN

    XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with Modbus® output and local HART® interface port, configured for XNX toxic and oxygen sensors.

    XNX-AMSE-FNNNN

    XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with optional Foundation Fieldbus™ output, configured for XNX toxic and oxygen sensors.

    XNX-AMSE-FHNNN

    XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with optional Foundation Fieldbus™ output and local HART® interface port, configured for XNX toxic and oxygen sensors.


    XNX Aluminium Transmitter UL/CSA for use with XNX Toxic and Oxygen Sensors


    XNX-UTAE-NNNNN

    XNX Transmitter, HART® over 4-20mA output, UL/CSA, 4 x 3/4"NPT entries, painted Aluminium, configured for XNX toxic and oxygen sensors

    XNX-UTAE-NHNNN

    XNX Transmitter, HART® over 4-20mA output and local HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted Aluminium, configured for XNX toxic and oxygen sensors

    XNX-UTAE-RNNNN

    XNX Transmitter, HART® over 4-20mA output and 3 fault/alarm relays, UL/CSA, 4 x 3/4"NPT entries, painted Aluminium, configured for XNX toxic and oxygen sensors

    XNX-UTAE-RHNNN

    XNX Transmitter, HART® over 4-20mA output and 3 fault/alarm relays and local HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted Aluminium, configured for XNX toxic and oxygen sensors

    XNX-UTAE-MNNNN

    XNX Transmitter, HART® over 4-20mA and Modbus output, UL/CSA, 4 x 3/4"NPT entries, painted Aluminium, configured for XNX toxic and oxygen sensors

    XNX-UTAE-MHNNN

    XNX Transmitter, HART® over 4-20mA and Modbus output and local HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted Aluminium, configured for XNX toxic and oxygen sensors

    XNX-UTAE-FNNNN

    XNX Transmitter, HART® over 4-20mA and Foundation Fieldbus™ output, UL/CSA, 4 x 3/4"NPT entries, painted Aluminium, configured for XNX toxic and oxygen sensors

    XNX-UTAE-FHNNN

    XNX Transmitter, HART® over 4-20mA and Foundation Fieldbus™ output and local HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted Aluminium, configured for XNX toxic and oxygen sensors

    XNX Stainless Steel Transmitter UL/CSA for use with XNX Toxic and Oxygen Sensors

    XNX-UTSE-NNNNN

    XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, configured for XNX toxic and oxygen sensors.

    XNX-UTSE-NHNNN

    XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with local HART® interface port, configured for XNX toxic and oxygen sensors.

    XNX-UTSE-RNNNN

    XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with alarm and fault relay outputs, configured for XNX toxic and oxygen sensors.

    XNX-UTSE-RHNNN

    XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with alarm and fault relay outputs and local HART® interface port, configured for XNX toxic and oxygen sensors.

    XNX-UTSE-MNNNN

    XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with Modbus® output, configured for XNX toxic and oxygen sensors.

    XNX-UTSE-MHNNN

    XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with Modbus® output and local HART® interface port, configured for XNX toxic and oxygen sensors.

    XNX-UTSE-FNNNN

    XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with optional Foundation Fieldbus™ output, configured for XNX toxic and oxygen sensors.

    XNX-UTSE-FHNNN

    XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with optional Foundation Fieldbus™ output and local HART® interface port, configured for XNX toxic and oxygen sensors.


    3.2. XNX TOXIC AND OXYGEN CARTRIDGES With SENSORS

    A range of toxic and oxygen sensors for use with the XNX transmitter. Sensors have replaceable cartridges.


    XNXXSO1SS

    XNX sensor Oxygen 0-25%VOL

    XNXXSC1SS

    XNX sensor Carbon Monoxide 0-300ppm (100 to 999ppm, 100ppm)

    XNXXSH3SS

    XNX sensor Hydrogen Sulfide 0-15ppm

    XNXXSH1SS

    XNX sensor Hydrogen Sulfide 0-15ppm (10 to 50ppm, 1ppm)

    XNXXSH2SS

    XNX sensor Hydrogen Sulfide 0-100ppm (50 to 500ppm, 10ppm)

    XNXXSL1SS

    XNX sensor Chlorine 0-5.0ppm (5.0 to 20.0ppm, 5.0ppm)

    XNXXSL2SS

    XNX sensor Chlorine Low Range, 0-5.00ppm

    XNXbbb1SS

    XNX sensor Sulfur Dioxide 0-15.0ppm (5.0 to 20.0ppm, 5.0ppm)

    XNXbbb2SS

    XNX sensor Sulfur Dioxide 0-50.0ppm (20.0 to 50.0ppm, 10.0ppm)

    XNXXSX1SS

    XNX sensor Chlorine Dioxide 0-1.00ppm

    XNXXSM1SS

    XNX sensor Nitrogen Monoxide 0-100ppm

    XNXXSN1SS

    XNX sensor Nitrogen Dioxide 0-10.0ppm (5.0 to 50.0ppm, 5.0ppm)

    XNXXSG1SS

    XNX sensor Hydrogen 0-1000ppm

    XNXXSG2SS

    XNX sensor Hydrogen 0-10,000ppm

    XNXXSA1SS

    XNX sensor Ammonia 0-200ppm (50 to 200ppm, 50ppm)

    XNXXSA2SS

    XNX sensor Ammonia 0-1000ppm (200 to 1000ppm, 50ppm)

    XNXXSR1SS

    XNX sensor Hydrogen Chloride 0-10ppm (10.0 to 20.0ppm, 1.0ppm)

    XNXXSF1SS

    XNX sensor Hydrogen Fluoride 0-12.0ppm

    XNXXSP1SS

    XNX sensor Phosphine 0-1.2ppm

    XNXXSY1SS

    XNX sensor Hydrogen Cyanide 0-30.0ppm (Fixed Scale)

    XNXXSU1SS

    XNX sensor Fluorine 4 ppm

    XNXXSE1SS

    XNX Cartridge, Ethylene Oxide (ETO), 25.0ppm (user-selectable from 20.0ppm to 50.0ppm)


    3.3. XNX REPLACEMENT TOXIC AND OXYGEN SENSOR Cell

    Replacement toxic and oxygen sensor cell for use in the XNX toxic and oxygen sensor.

    XNXO1SS

    XNX Cartridge Oxygen 0-25%VOL

    XNXC1SS

    XNX Cartridge Carbon Monoxide 0-300ppm (100 to 500ppm, 100ppm)

    XNXH3SS

    XNX Cartridge Hydrogen Sulfide 0-5ppm (1.5 to 5ppm, 0.1ppm)

    XNXH1SS

    XNX Cartridge Hydrogen Sulfide 0-15ppm (10 to 50ppm, 1ppm)

    XNXH2SS

    XNX Cartridge Hydrogen Sulfide 0-100ppm (50 to 500ppm, 10ppm)

    XNXL1SS

    XNX Cartridge Chlorine 0-5.0ppm

    XNXS1SS

    XNX Cartridge Sulfur Dioxide 0-15.0ppm (5.0 to 20.0ppm, 5.0ppm)

    XNXX1SS

    XNX Cartridge Chlorine Dioxide 0-1.00ppm

    XNXM1SS

    XNX Cartridge Nitrogen Monoxide 0-100ppm

    XNXN1SS

    XNX Cartridge Nitrogen Dioxide 0-10.0ppm (5.0 to 50.0ppm, 5.0ppm)

    XNXG1SS

    XNX Cartridge Hydrogen 0-1000ppm

    XNXG2SS

    XNX Cartridge Hydrogen 0-10,000ppm

    XNXR1SS

    XNX Cartridge Hydrogen Chloride 0-10ppm (10.0 to 20.0ppm, 1.0ppm)

    XNXA1SS

    XNX Cartridge Ammonia 0-200ppm (50 to 200ppm, 50ppm)

    XNXA2SS

    XNX Cartridge Ammonia 0-1000ppm (200 to 1000ppm, 50ppm)

    XNXF1SS

    XNX Cartridge Hydrogen Fluoride 0-12.0ppm

    XNXP1SS

    XNX Cartridge Phosphine 0-1.2ppm

    XNXY1SS

    XNX Cartridge Hydrogen Cyanide 0-30.0ppm (Fixed Scale)

    XNXE1SS

    XNX Cartridge Fluorine 4ppm

    XNXE1SS

    XNX Cell Kit, Ethylene Oxide (ETO), 25.0ppm (user-selectable from 20.0ppm to 50.0ppm)

    4. XNX Universal Transmitter- for use with Optima Plus Or Searchline Excel Detectors

    XNX Transmitter for use with Optima Plus and Searchline Excel IR detectors.  Order Optima Plus and Searchline Excel detectors separabbby from the appropriate section in the price list. Note kit part numbers including standard XNX transmitter configurations have been created for Searchline Excel detectors (see appropriate section in price list).


    4.1. INSTRUMENT


    XNX Aluminuim Transmitter ATEX/IEC for use with Optima Plus and Searchline Excel Detectors


    XNX-AMAI-NNNNN

    XNX Transmitter, HART® over 4-20mA output, ATEX/IECEx, 5 x M25 entries, painted Aluminium, configured for Optima Plus and Excel

    XNX-AMAI-NHNNN

    XNX Transmitter, HART® over 4-20mA output and local HART® interface port, ATEX/IECEx, 4 x M25 entries, painted Aluminium, configured for Optima Plus and Excel

    XNX-AMAI-RNNNN

    XNX Transmitter, HART® over 4-20mA output and 3 fault/alarm relays, ATEX/IECEx, 5 x M25 entries, painted Aluminium, configured for Optima Plus and Excel

    XNX-AMAI-RHNNN

    XNX Transmitter, HART® over 4-20mA output and 3 fault/alarm relays and local HART® interface port, ATEX/IECEx, 4 x M25 entries, painted Aluminium, configured for Optima Plus and Excel

    XNX-AMAI-MNNNN

    XNX Transmitter, HART® over 4-20mA and Modbus output, ATEX/IECEx, 5 x M25 entries, painted Aluminium, configured for Optima Plus and Excel

    XNX-AMAI-MHNNN

    XNX Transmitter, HART® over 4-20mA and Modbus output and local HART® interface port, ATEX/IECEx, 4 x M25 entries, painted Aluminium, configured for Optima Plus and Excel

    XNX-AMAI-FNNNN

    XNX Transmitter, HART® over 4-20mA and Foundation Fieldbus™ output, ATEX/IECEx, 5 x M25 entries, painted Aluminium, configured for Optima Plus and Excel

    XNX-AMAI-FHNNN

    XNX Transmitter, HART® over 4-20mA and Foundation Fieldbus™ output and local HART® interface port, ATEX/IECEx, 4 x M25 entries, painted Aluminium, configured for Optima Plus and Excel


    XNX Stainless Steel Transmitter ATEX/IEC for use with Optima Plus and Searchline Excel Detectors


    XNX-AMSI-NNNNN

    XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, configured for Optima Plus and Searchline Excel.

    XNX-AMSI-NHNNN

    XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with local HART® interface port, configured for Optima Plus and Searchline Excel.

    XNX-AMSI-RNNNN

    XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with alarm and fault relay outputs, configured for Optima Plus and Searchline Excel.

    XNX-AMSI-RHNNN

    XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with alarm and fault relay outputs and local HART® interface port, configured for Optima Plus and Searchline Excel.

    XNX-AMSI-MNNNN

    XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with Modbus® output, configured for Optima Plus and Searchline Excel.

    XNX-AMSI-MHNNN

    XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with Modbus® output and local HART® interface port, configured for Optima Plus and Searchline Excel.

    XNX-AMSI-FNNNN

    XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with optional Foundation Fieldbus™ output, configured for Optima Plus and Searchline Excel.

    XNX-AMSI-FHNNN

    XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with optional Foundation Fieldbus™ output and local HART® interface port, configured for Optima Plus and Searchline Excel.


    XNX Aluminuim Transmitter UL/CSA for use with Optima Plus and Searchline Excel Detectors


    XNX-UTAI-NNNNN

    XNX Transmitter, HART® over 4-20mA output, UL/CSA, 5 x 3/4"NPT entries, painted Aluminium, configured for Optima Plus and Excel

    XNX-UTAI-NHNNN

    XNX Transmitter, HART® over 4-20mA output and local HART® interface port, UL/CSA, 4 x 3/4"NPT entries, painted Aluminium, configured for Optima Plus and Excel

    XNX-UTAI-RNNNN

    XNX Transmitter, HART® over 4-20mA output and 3 fault/alarm relays, UL/CSA, 5 x 3/4"NPT entries, painted Aluminium, configured for Optima Plus and Excel

    XNX-UTAI-RHNNN

    XNX Transmitter, HART® over 4-20mA output and 3 fault/alarm relays and local HART® interface port, UL/CSA, 4 x 3/4"NPT entries, painted Aluminium, configured for Optima Plus and Excel

    XNX-UTAI-MNNNN

    XNX Transmitter, HART® over 4-20mA and Modbus output, UL/CSA, 5 x 3/4"NPT entries, painted Aluminium, configured for Optima Plus and Excel

    XNX-UTAI-MHNNN

    XNX Transmitter, HART® over 4-20mA and Modbus output and local HART® interface port, UL/CSA, 4 x 3/4"NPT entries, painted Aluminium, configured for Optima Plus and Excel

    XNX-UTAI-FNNNN

    XNX Transmitter, HART® over 4-20mA and Foundation Fieldbus™ output, UL/CSA, 5 x 3/4"NPT entries, painted Aluminium, configured for Optima Plus and Excel

    XNX-UTAI-FHNNN

    XNX Transmitter, HART® over 4-20mA and Foundation Fieldbus™ output and local HART® interface port, UL/CSA, 4 x 3/4"NPT entries, painted Aluminium, configured for Optima Plus and Excel


    XNX Stainless Steel Transmitter UL/CSA for use with Optima Plus and Searchline Excel Detectors


    XNX-UTSI-NNNNN

    XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, configured for Optima Plus and Searchline Excel.

    XNX-UTSI-NHNNN

    XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with local HART® interface port, configured for Optima Plus and Searchline Excel.

    XNX-UTSI-RNNNN

    XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with alarm and fault relay outputs, configured for Optima Plus and Searchline Excel.

    XNX-UTSI-RHNNN

    XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with alarm and fault relay outputs and local HART® interface port, configured for Optima Plus and Searchline Excel.

    XNX-UTSI-MNNNN

    XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with Modbus® output, configured for Optima Plus and Searchline Excel.

    XNX-UTSI-MHNNN

    XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with Modbus® output and local HART® interface port, configured for Optima Plus and Searchline Excel.

    XNX-UTSI-FNNNN

    XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with optional Foundation Fieldbus™ output, configured for Optima Plus and Searchline Excel.

    XNX-UTSI-FHNNN

    XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with optional Foundation Fieldbus™ output and local HART® interface port, configured for Optima Plus and Searchline Excel.



    5. Searchline Excel kits with XNX Transmitters

    Searchline Excel kits including standard XNX transmitter configured  with HART® over 4-20mA output and local HART® port. For Searchline Excel kits including other XNX transmitter configurations contact Honeywell Analytics.
    Part No. Key


    5.1. INSTRUMENT


    Searchline Excel kits including standard XNX transmitter with HART® over 4-20mA outputs.



    Searchline Excel Short Range 5m – 40m (15ft - 130ft)


    02104-N-XSAA

    Short range system 5m to 40m ATEX/IECEx complete TXR and RXR system, fully wired with flexible conduit, SS316 mounting plates and brackets, Aluminium XNX with local HART® interface port and JB.

    02104-N-bbbA

    Short range system 5m to 40m ATEX/IECEx complete TXR and RXR system, fully wired with flexible conduit, SS316 mounting plates and brackets, Stainless Steel XNX with local HART® interface port JB

    02104-N-XSAU

    Short range system 5m to 40m UL complete TXR and RXR system, fully wired with flexible conduit, SS316 mounting plates, brackets, Aluminium XNX and junction box.

    02104-N-bbbU

    Short range system 5m to 40m UL complete TXR and RXR system, fully wired with flexible conduit, SS316 mounting plates, brackets, Stainless Steel XNX and junction box.

    02104-N-XSAC

    Short range system 5m to 40m CSA complete TXR and RXR system, fully wired with flexible conduit, SS316 mounting plates, brackets, Aluminium XNX and junction box.

    02104-N-bbbC

    Short range system 5m to 40m CSA complete TXR and RXR system, fully wired with flexible conduit, SS316 mounting plates, brackets, Stainless Steel XNX and junction box.

    02104-N-NSNA

    Short range system 5m to 40m ATEX/IECEx complete TXR and RXR system, SS316 mounting plates and fitting for XNX. Add XNX and Junction box as required


    Searchline Excel Medium Range 20m – 120m


    02104-N-XMAA

    Medium range system 20m to 120m ATEX/IECEx complete TXR and RXR system, fully wired with flexible conduit, SS316 mounting plates and brackets, Aluminium XNX with local HART® interface port and JB

    02104-N-XMSA

    Medium range system 20m to 120m ATEX/IECEx complete TXR and RXR system, fully wired with flexible conduit, SS316 mounting plates and brackets, Stainless Steel XNX with local HART® interface port and JB

    02104-N-XMAU

    Medium range system 20m to 120m UL complete TXR and RXR system, fully wired with flexible conduit, SS316 mounting plates, brackets, Aluminium XNX and junction box.

    02104-N-XMSU

    Medium range system 20m to 120m UL complete TXR and RXR system, fully wired with flexible conduit, SS316 mounting plates, brackets, Stainless Steel XNX and junction box.

    02104-N-XMAC

    Medium range system 40m to 120m CSA complete TXR and RXR system, fully wired with flexible conduit, SS316 mounting plates, brackets, Aluminium XNX and junction box.

    02104-N-XMSC

    Medium range system 40m to 120m CSA complete TXR and RXR system, fully wired with flexible conduit, SS316 mounting plates, brackets, Stainless Steel XNX and junction box.

    02104-N-NMNA

    Excel line-of-sight gas detection system (without XNX, please order required XNX separabbby), medium range (40 to 120m), 4 to 20mA output, ATEX/IECEx, fully wired with flexible conduit, electro polished 316SS. Includes Tx, Rx, 316SS mounting plates, brackets and hardware. XNX and junciton boxes to be ordered seperabbby.


    Searchline Excel Long Range 20m – 200m


    02104-N-XLAA

    Long range system 20m to 200m ATEX/IECEx complete TXR and RXR system, fully wired with flexible conduit, SS316 mounting plates and brackets, Aluminium XNX with local HART® interface port and JB

    02104-N-XLSA

    Long range system 20m to 200m ATEX/IECEx complete TXR and RXR system, fully wired with flexible conduit, SS316 mounting plates and brackets, Stainless Steel XNX with local HART® interface port JB

    02104-N-XLAU

    Long range system 20m to 200m UL complete TXR and RXR system, fully wired with flexible conduit, SS316 mounting plates, brackets, Aluminium XNX and junction box.

    02104-N-XLSU

    Long range system 20m to 200m UL complete TXR and RXR system, fully wired with flexible conduit, SS316 mounting plates, brackets, Stainless Steel XNX and junction box.

    02104-N-XLAC

    Long range system 120m to 200m CSA complete TXR and RXR system, fully wired with flexible conduit, SS316 mounting plates, brackets, Aluminium XNX and junction box.

    02104-N-XLSC

    Long range system 120m to 200m CSA complete TXR and RXR system, fully wired with flexible conduit, SS316 mounting plates, brackets, Stainless Steel XNX and junction box.

    02104-N-NLNA

    Excel line-of-sight gas detection system (without XNX, please order required XNX separabbby), long range (120 to 200m), 4 to 20mA output, ATEX/IECEx, fully wired with flexible conduit, electro polished 316SS. Includes Tx, Rx, 316SS mounting plates, brackets and hardware. XNX and junciton boxes to be ordered seperabbby.


    5.2. XNX and Searchline Excel Alignment Kits


    02104-N-4006X

    Short Range Excel & XNX alignment and conbbbbity kit including bbbescope, carry case and test filters (no SHC1)

    02104-N-4007X

    Long/Medium Range Excel & XNX alignment and conbbbbity kit including bbbescope, carry case and test filters (no SHC1)


    6. XNX Universal Transmitter Accessories and Spare Parts


    6.1. XNX ACCESSORIES & SPARES


    1226A0358

    Pipe Mount Kit

    1226A0355

    Ceiling Mount Bracket Kit

    S3KDMK

    Duct mounting kit for Series 3000 and XNX EC toxic sensors

    1226A0382

    MPD Interface Adaptor  (for use with S3KDMK Duct Mount Kit)

    1226A0411

    Calibration Gas Flow Adaptor (for use with MPD)

    S3KCAL

    Calibration cup (flow adapter) for Series 3000 and XNX EC toxic sensors

    S3KRMK

    Remote mounting kit for Series 3000 and XNX EC toxic sensors

    02000-A-1645

    Flow Housing Assembly (for Sensepoint, Signalpoint, Sabbblite (with adapter), XNX MPD and Series 2000)

    00780-A-0035

    Flow Housing (full stainless steel, for high temp applications)

    S3KWP

    Weatherproof housing with bump test port for use with Series 3000 and XNX EC toxic sensors

    SPXCDWP

    Standard Weather Protection, uses for ECC toxic sensor cartridges in outdoor

    02000-A-1640

    Weatherproof cap for use with combustible detector including remote gassing nozzle (for Sensepoint, Signalpoint, Sabbblite (with adapter), XNX MPD and Series 2000)

    02000-A-1635

    Weatherproof cap for use with toxic detector including remote gassing nozzle (for Sensepoint, Signalpoint, Sabbblite (with adapter), XNX MPD and Series 2000)

    02000-A-1642

    Collecting cone for use with flammable detector (for Sensepoint, Signalpoint, Sabbblite (with adapter), XNX MPD and Series 2000)

    SPXCDCC

    Collecting cone for use with lighter than air gases

    2441-0022

    UL/CSA Aluminium Junction Box Assembly (for remote mount of MPD sensors)

    00780-A-0100

    Honeywell Junction Box- Bartec OTB122 With Continuity Plate 1 X 25mm - 3 X 20mm Entries - ATEX Approved

    MCT404-XA-02-00

    Honeywell HART Communicator for use with XNX Range and Optima Plus gas detectors, Intrinsically-safe, with FM Class I, Div 1/Zone 1, ATEX and IECEx Zone 1 approvals. Including rechargeable battery, mains powered charger and docking station

    50079567-011

    Leather carrying case for MCT404 (Stylus & shoulder strap included)

    10000-A-0004

    SS316 Mounting Plate for 2" to 2.5" pipe mounting (Sourced from HAAP Singapore)

    10000-A-0054

    XNX Transmitter Sunshade (Sourced from HAAP Singapore)

    10000-A-0190

    2” Pipe mount “V” bracket, M10, including washers & nuts, SS316 (Sourced from HAAP Singapore)

    XNX-FLOW

    SS316 Flow Housing for ECC Sensors - for Aspirated Sampling Systems (Sourced from HAAP Singapore)

    1226A0354

    Remote Gassing Kit

    1226-0257

    M25 Stopping Plug w/ protective cap and O-ring

    1226-0258

    3/4" NPT Stopping Plug w/ protective cap and  O-ring

    0235-0238

    Replacement O-ring for XNX front cover

    1226A0302

    Terminal Block Assembly 6-Pin for XNX EC

    1226A0304

    Terminal Block Assembly 9-Pin for XNX mV

    1226A0305

    IR Terminal Block Assembly Kit includes: 9-Pin &
    2 Pin blocks

    1226A0306

    Relay Terminal Block Assembly Kit includes: 9-Pin and 2-Pin blocks

    1226A0307

    Terminal Block Assembly 10-Pin for XNX Modbus

    1226-9001

    XNX Transmitter Spare Pod, Infrared Personality, No Options

    1226-9002

    XNX Transmitter Spare Pod, Infrared Personality, Relay Option

    1226-9003

    XNX Transmitter Spare Pod, Infrared Personality, ModBus Options

    1226-9004

    XNX Transmitter Spare Pod, Infrared Personality, Foundation Fieldbus Options

    1226-9009

    XNX Transmitter Spare Pod, Millivolt Personality, No Options

    1226-9010

    XNX Transmitter Spare Pod, Millivolt Personality, Relay Option

    1226-9011

    XNX Transmitter Spare Pod, Millivolt Personality, ModBus Option

    1226-9012

    XNX Transmitter Spare Pod, Millivolt Personality, Foundation Fieldbus Options

    1226-9005

    XNX Transmitter Spare Pod, Electrochemical Personality, No Options

    1226-9006

    XNX Transmitter Spare Pod, Electrochemical Personality,  Relay Option

    1226-9007

    XNX Transmitter Spare Pod, Electrochemical Personality,  ModBus Option

    1226-9008

    XNX Transmitter Spare Pod, Electrochemical Personality, Foundation Fieldbus Options

    XNX-RLY

    Relay Option

    XNX-MB

    ModBus Option

    XNX-FFB

    Foundation Fieldbus Option

    SPXNXSERVK

    XNX Service Kit, Including Replacement O-ring for XNX front cover, I.S. modules screws (2 pieces), Earth screw and bracket (3 pieces), O-ring for MPD housing, MPD Sinter O-ring, MPD Sinter locking screw (set screw), ECC sensor - 3 off O-rings, ECC Sensor Lid O-ring, ECC sensor lid - locking screw (set screw)

    SPXNXTOOLK

    XNS Tool Kit, Including Magnetic Wand/Screwdriver, Small Screwdriver (for use with Relay board and IR personality board), HEX L-KEY 2.0MM, HEX-L-KEY 1.5MM X 3.06"L


    上海宛畅实业有限公司是一家自动化设备及工业零部件的专业供应商.公司成立于2012年,专注于为石油,化工,电力,钢铁,制药,环保等领域终端用户提供工程配套自动化设备及工控备件.


    公司依托国内外一批成熟大客户:中海油渤海钻井平台,山东瑞星化工,河北沙河电厂,PAKISTAN NATIONAL REFINERY LIMITED,Petro Oil Supply SDN BHD,THUSO MOLOSIWA BOTSWANA POWER CORPORATION,巴西PAMPA1X345MW燃煤电站等,拥有一批非常优势的品牌资源.

    主营:Honeywell霍尼韦尔气体探测,Micro Motion艾默生高准质量流量计,罗斯蒙特变送器,霍尼韦尔控制系统与集成,燃烧控制产品,环境自控,阀门执行器、开关等。

    #上海宛畅实业有限公司#专业销售欧美日韩进口的工控产品、仪器仪表等工控备件!

    原装进口、型号全、价格优,欢迎询价!

    联系电话:021-37824198 / 17740803693

    QQ:1093845670/1016549297 专业为您选型。

    官网:http://www.parts4automation.com/cn

在线询盘/留言
  • 免责声明:以上所展示的信息由企业自行提供,内容的真实性、准确性和合法性由发布企业负责,本网对此不承担任何保证责任。我们原则 上建议您选择本网高级会员或VIP会员。
    0571-87774297